Main
range of productEasyPact
product or component typeCircuit breaker
device short nameEasypact EZC100H
circuit breaker nameEasypact EZC100H
device applicationDistribution
poles description2P
protected poles description2t
network typeDC
AC
network frequency50/60 Hz
[In] rated current63 A at 40 °C
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
[Ue] rated operational voltage550 V AC 50/60 Hz conforming to IEC 60947-2
250 V DC conforming to IEC 60947-2
breaking capacity codeH
breaking capacity10 kA Icu at 125 V DC 1P conforming to IEC 60947-2
10 kA Icu at 250 V DC 2P conforming to IEC 60947-2
10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2
20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
30 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2
30 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity5 kA at 125 V DC conforming to IEC 60947-2
5 kA at 250 V DC conforming to IEC 60947-2
5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2
15 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2
25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2
7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2
suitability for isolationYes conforming to IEC 60947-2
utilisation categoryCategory A
trip unit nameTM-D
trip unit technologyThermal-magnetic
trip unit rating63 A at 50 °C
protection typeOverload protection
Short-circuit protection
pollution degree3 conforming to IEC 60947

Complementary
control typeToggle
mounting modeFixed
mounting supportBackplate
upside connectionFront
downside connectionFront
mechanical durability8500 cycles
electrical durabilityCategory A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
connection pitch25 mm
local signallingPositive contact indication
neutral protection settingWithout protection
earth-leakage protectionWithout
height130 mm
width50 mm
depth60 mm
Environment
standardsEN/IEC 60947-1
EN/IEC 60947-2
GB/T 14048.2
JIS C8201-2-2
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to EN 50102
ambient air temperature for operation-25…70 °C
ambient air temperature for storage-35…85 °C
Packing Units
Unit Type of Package 1PCE
Package 1 Length13.6 cm
Number of Units in Package 11
Package 3 Width30.0 cm
Package 3 Weight22.025 kg
Package 2 Width30.0 cm
Package 2 Height15.0 cm
Package 2 Weight10.683 kg
Number of Units in Package 336
Unit Type of Package 3S03
Package 3 Height30.0 cm
Package 3 Length40.0 cm
Package 1 Width9.2 cm
Package 1 Height5.6 cm
Package 1 Weight571.0 g
Number of Units in Package 218
Unit Type of Package 2S02
Package 2 Length40.0 cm


100 Rate %
I haven't set up the buyer's impression yet. Please wait with me~
No comment

User discussion circle

Subscribe to get more info
Compare

1

You can also continue adding

2

You can also continue adding

3

You can also continue adding

4

You can also continue adding