There are no items in the shopping cart.
Condition:New
Brand:SCHNEIDER ELECTRIC
Model:LV432699
Code:LV432699SCH
Weight:1.000 KG
MOQ:0
Number of Poles :3P
Current Rating:400A

More parameters>>

Quantity
On Hand    Group Stock    ETA Delivery   
Shipping time may vary.
VitalMRO rep will advise.


 ~ 

Product Filter

Clear All

Number of Poles
Current Rating
Range
Coil Voltage (AC)
Contact Voltage Rating
Breaking Capacity
  • Product
  • Attribute
  • Price
  • Add To Cart
  • Products Detail
  • Specification parameter
  • Products Q&A
Mobile phone purchase
goods qr code
Add To Cart
Price:
Quantity:
Inventory  PcsAccount Inventory  Pcs

Products Detail

Replacement Suggest:


Main
rangeComPact
product nameComPact NSX
range of productComPact NSX400...630
device short nameNSX400N
product or component typeCircuit breaker
device applicationDistribution
Number of poles3P
protected poles description3t
[In] rated current400 A at 40 °C
[Ue] rated operational voltage690 V AC 50/60 Hz
network typeAC
network frequency50/60 Hz
suitability for isolationYes conforming to EN/IEC 60947-2
utilisation categoryCategory A
[Icu] rated ultimate short-circuit breaking capacity85 kA at 240 V AC 50/60 Hz conforming to UL 508
22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
20 kA at 600 V AC 50/60 Hz conforming to UL 508
50 kA at 480 V AC 50/60 Hz conforming to UL 508
50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
42 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
Performance levelN 50 kA 415 V AC
trip unit nameMicrologic 5.3 A
trip unit technologyElectronic
trip unit protection functionsLSI
control typeToggle
Circuit breaker mounting modeFixed

Complementary
[Ui] rated insulation voltage800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage8 kV
[Ics] rated service short-circuit breaking capacity11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
42 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
mechanical durability15000 cycles
electrical durability3000 cycles at 690 V In
6000 cycles at 690 V In/2
6000 cycles at 440 V In
12000 cycles at 440 V In/2
mounting supportBackplate
upside connectionFront
downside connectionFront
connection pitch45 mm
protection typeL : for overload protection (long time)
S : for short time short-circuit protection
I : for instantaneous short-circuit protection
trip unit rating400 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection)Adjustable
[Ir] long-time protection pick-up adjustment range160...400 A
Long-time protection delay adjustment type trAdjustable
[tr] long-time protection delay adjustment range15…400 s at 1.5 x Ir
0.35…11 s at 7.2 x Ir
0.5…16 s at 6 x Ir
thermal memory20 minutes before and after tripping
Short-time protection pick-up adjustment type IsdAdjustable
[Isd] Short-time protection pick-up adjustment range1.5...10 x Ir
Short-time protection delay adjustment type tsdAdjustable
[tsd] Short-time protection delay adjustment range0…0.4 s
Instantaneous protection pick-up adjustment type IiAdjustable
[Ii] instantaneous protection pick-up adjustment range1.5...12 x In
earth-leakage protectionWithout
zone selective interlocking ZSIWith
Number of slots for electrical auxiliaries6 slot(s)
local signallingFlashing LED (green) for ready to operate
LED 105 % Ir (red) for overload
LED 90 % Ir (orange) for overload
display typeLCD display
type of measurementAmmeter
communication of dataEnergy metering
Maximeters/minimeters
Demand current and power
Instantaneous and demand values
Protection and alarm settings
Maintenance indicators
Power quality
Time-stamped histories and event tables
Width (W)140 mm
Height (H)255 mm
Depth (D)110 mm
net weight6.05 kg
Environment
standardsEN/IEC 60947
product certificationsCCC
EAC
Marine
overvoltage categoryClass II
electrical shock protection classClass II
pollution degree3 conforming to IEC 60664-1
IP degree of protectionIP40 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
ambient air temperature for operation-25…70 °C
ambient air temperature for storage-40…85 °C
relative humidity0…95 %
operating altitude0...2000 m without derating
2000 m...5000 m with derating