PowerLogic

product name
PowerLogic PM5350

device short name
PM5350

product or component type
Power meter

Complementary
power quality analysis
total demand distortion
total harmonic distortion

device application
Power monitoring

type of measurement
Current
Voltage
Frequency
Power factor
Energy
Phase angle
Apparent power
Active power
Reactive power

supply voltage
85...265 V AC 45...65 Hz
100...300 V DC

network frequency
50 Hz
60 Hz

[In] rated current
5 A
1 A

type of network
1P + N
3P + N
3P

maximum power consumption in VA
9.6 VA

ride-through time
80 ms 120 V AC typical
100 ms 230 V AC typical
100 ms 415 V AC typical

display type
Backlit LCD

display resolution
6 lines

sampling rate
32 samples/cycle

measurement current
0…1 A
0…5 A

analogue input type
Current 0.05...9 A (impedance <= 0.3 Ohm)

measurement voltage
20…690 V AC phase to phase
20…400 V AC phase to neutral

frequency measurement range
45…70 Hz

number of inputs
4 digital

measurement accuracy
Current 0.3 %
Voltage 0.3 %
Frequency 0.05 %
Power factor +/- 0.005

accuracy class
Class 0.5S active energy conforming to IEC 62053-22
Class 0.5 active energy conforming to IEC 61557-12
Class 3 reactive energy conforming to IEC 62053-23
Class 2 reactive energy conforming to IEC 61557-12
Class 0.5 power conforming to IEC 61557-12

number of outputs
2 relay

information displayed
Tariff (4)

communication port protocol
JBUS
Modbus RTU and ASCII at 9.6, 19.2 and 38.4 kbauds

communication port support
Terminal block: RS485

data recording
Min/max of instantaneous values
Alarms

connections - terminals
Voltage circuit: screw terminal block4
Control circuit: screw terminal block2
Current transformer: screw terminal block6
Input/output circuit: screw terminal block6
Relay output: screw terminal block4
Ethernet network: RJ45 connector

mounting mode
Flush-mounted

type of installation
Indoor installation

standards
IEC 61010-1

product certifications
CE
CULus

width
96 mm

depth
44 mm

height
96 mm

net weight
0.25 kg

Environment
electromagnetic compatibility
Limitation of voltage changes, voltage fluctuations and flicker in low-voltage conforming to IEC 61000-3-3
Electrostatic discharge conforming to IEC 61000-4-2
Susceptibility to electromagnetic fields conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4
1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5
Conducted RF disturbances conforming to IEC 61000-4-6
Immunity to impulse waves conforming to IEC 61000-4-12
Conducted and radiated emissions class A conforming to EN 55011
Limits for harmonic current emissions conforming to IEC 61000-3-2

overvoltage category
III

IP degree of protection
IP30 back: conforming to IEC 60529
IP51 front face: conforming to IEC 60529

relative humidity
0…95 % at 50 °C

pollution degree
2

ambient air temperature for operation
-40…85 °C

ambient air temperature for storage
-25…70 °C
Submitter Question and Answer
ask testing
100 Rate %
I haven't set up the buyer's impression yet. Please wait with me~
No comment

User discussion circle

Subscribe to get more info
Compare

1

You can also continue adding

2

You can also continue adding

3

You can also continue adding

4

You can also continue adding