Product Filter
VitalMRO is Authorized Distributor for This Product.
range of product | Harmony XAC |
---|---|
product or component type | Pendant control station |
device short name | XACA |
control station type Double insulated enclosure material Polypropylene electrical circuit type Control circuit enclosure type Complete ready for use control station application Control of single speed hoist motor control station composition 8 push-buttons control button type First push-button 1 NC + 1 NO raise, slow
Second push-button 1 NC + 1 NO lower, slow
Fourth push-button 1 NC + 1 NO left, slow
Third push-button 1 NC + 1 NO right, slow
Fifth push-button 1 NC + 1 NO forward slow
Sixth push-button 1 NC + 1 NO reverse, slow
Eighth push-button 1 NC + 1 NO O
Seventh push-button 1 NC + 1 NO Iproduct compatibility ZB2BE102 + ZB2BE101 for each direction mechanical interlocking With mechanical interlocking between pairs control station colour Yellow connections - terminals Screw clamp terminals, 1 x 0.5...1 x 2.5 mm² without cable end
Screw clamp terminals, 1 x 0.5...2 x 1.5 mm² with cable endstandards EN/IEC 60947-5-1
UL 508
CSA C22.2 No 14
EN/IEC 60204-32product certifications GOST
CCCprotective treatment TH ambient air temperature for operation -25…70 °C ambient air temperature for storage -40…70 °C vibration resistance 15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 shock resistance 100 gn conforming to IEC 60068-2-27 overvoltage category Class II conforming to IEC 61140 IP degree of protection IP65 conforming to IEC 60529 IK degree of protection IK08 conforming to EN 50102 mechanical durability 1000000 cycles cable entry Rubber sleeve with stepped entry 8…26 mm contact code designation A600 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A
A600 AC-15, Ue = 600 V, Ie = 1.2 A conforming to IEC 60947-5-1 appendix A
Q600 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A
Q600 DC-13, Ue = 600 V, Ie = 0.1 A conforming to IEC 60947-5-1 appendix A[Ithe] conventional enclosed thermal current 10 A [Ui] rated insulation voltage 600 V (pollution degree 3) [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-1 contact operation Slow-break maximum resistance across terminals 25 MOhm operating force 13 N push-button short-circuit protection 10 A fuse protection by cartridge fuse type gG rated operational power in W 40 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
48 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
65 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix Cterminals description ISO n°1 (13-14)NO
(11-12)NCterminal identifier (11-12)NC
(13-14)NOnet weight 1.045 kg
Comments