VitalMRO is Authorized Distributor for This Product.
range of product | Altivar 12 |
---|---|
product or component type | Variable speed drive |
product destination | Asynchronous motors |
product specific application | Simple machine |
assembly style | With heat sink |
component name | ATV12 |
quantity per set | Set of 1 |
EMC filter | Integrated |
built-in fan | With |
network number of phases | 1 phase |
[Us] rated supply voltage | 200...240 V - 15...10 % |
motor power kW | 1.5 kW |
motor power hp | 2 hp |
communication port protocol | Modbus |
line current | 17.8 A at 200 V 14.9 A at 240 V |
speed range | 1…20 |
transient overtorque | 150…170 % of nominal motor torque depending on drive rating and type of motor |
asynchronous motor control profile | Sensorless flux vector control Quadratic voltage/frequency ratio Voltage/frequency ratio (V/f) |
IP degree of protection | IP20 without blanking plate on upper part |
noise level | 45 dB |
supply frequency 50/60 Hz +/- 5 % connector type 1 RJ45 (on front face) for Modbus physical interface 2-wire RS 485 for Modbus transmission frame RTU for Modbus transmission rate 4800 bit/s
9600 bit/s
19200 bit/s
38400 bit/snumber of addresses 1…247 for Modbus communication service Read holding registers (03) 29 words
Write single register (06) 29 words
Write multiple registers (16) 27 words
Read/write multiple registers (23) 4/4 words
Read device identification (43)prospective line Isc 1 kA continuous output current 7.5 A at 4 kHz maximum transient current 11.2 A for 60 s speed drive output frequency 0.5…400 Hz nominal switching frequency 4 kHz switching frequency 2...16 kHz adjustable
4...16 kHz with derating factorbraking torque Up to 70 % of nominal motor torque without braking resistor motor slip compensation Adjustable
Preset in factoryoutput voltage 200...240 V 3 phases electrical connection Terminal, clamping capacity: 5.5 mm², AWG 10 (L1, L2, L3, U, V, W, PA, PC) tightening torque 1.2 N.m insulation Electrical between power and control supply Internal supply for reference potentiometer: 5 V DC (4.75…5.25 V), <10 mA, protection type: overload and short-circuit protection
Internal supply for logic inputs: 24 V DC (20.4…28.8 V), <100 mA, protection type: overload and short-circuit protectionanalogue input number 1 analogue input type Configurable current AI1 0...20 mA 250 Ohm
Configurable voltage AI1 0...10 V 30 kOhm
Configurable voltage AI1 0...5 V 30 kOhmdiscrete input number 4 discrete input type Programmable LI1...LI4 24 V 18...30 V discrete input logic Negative logic (sink), > 16 V (state 0), < 10 V (state 1), input impedance 3.5 kOhm
Positive logic (source), 0...< 5 V (state 0), > 11 V (state 1)sampling duration 20 ms, tolerance +/- 1 ms for logic input
10 ms for analogue inputlinearity error +/- 0.3 % of maximum value for analogue input analogue output number 1 analogue output type AO1 software-configurable voltage: 0...10 V, impedance: 470 Ohm, resolution 8 bits
AO1 software-configurable current: 0...20 mA, impedance: 800 Ohm, resolution 8 bitsdiscrete output number 2 discrete output type Logic output LO+, LO-
Protected relay output R1A, R1B, R1C 1 C/Ominimum switching current 5 mA at 24 V DC for logic relay maximum switching current 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms logic relay
2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms logic relay
3 A 250 V AC resistive cos phi = 1 L/R = 0 ms logic relay
4 A 30 V DC resistive cos phi = 1 L/R = 0 ms logic relayacceleration and deceleration ramps U
S
Linear from 0 to 999.9 sbraking to standstill By DC injection, <30 s protection type Line supply overvoltage
Line supply undervoltage
Overcurrent between output phases and earth
Overheating protection
Short-circuit between motor phases
Against input phase loss in three-phase
Thermal motor protection via the drive by continuous calculation of I²tfrequency resolution Analog input: converter A/D, 10 bits
Display unit: 0.1 Hztime constant 20 ms +/- 1 ms for reference change marking CE operating position Vertical +/- 10 degree height 142 mm width 105 mm depth 156.2 mm net weight 1.4 kg functionality Basic specific application Commercial equipment Variable speed drive application selection Mixer Commercial equipment
Other application Commercial equipment
Ironing Textilemotor starter type Variable speed drive electromagnetic compatibility Electrical fast transient/burst immunity test level 4 conforming to EN/IEC 61000-4-4
Electrostatic discharge immunity test level 3 conforming to EN/IEC 61000-4-2
Immunity to conducted disturbances level 3 conforming to EN/IEC 61000-4-6
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to EN/IEC 61000-4-3
Surge immunity test level 3 conforming to EN/IEC 61000-4-5
Voltage dips and interruptions immunity test conforming to EN/IEC 61000-4-11electromagnetic emission Radiated emissions environment 1 category C2 conforming to EN/IEC 61800-3 2...16 kHz shielded motor cable
Conducted emissions with integrated EMC filter environment 1 category C1 conforming to EN/IEC 61800-3 2, 4, 8, 12 and 16 kHz shielded motor cable <5 m
Conducted emissions with additional EMC filter environment 1 category C1 conforming to EN/IEC 61800-3 4...12 kHz shielded motor cable <20 m
Conducted emissions with additional EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 4...12 kHz shielded motor cable <50 m
Conducted emissions with additional EMC filter environment 2 category C3 conforming to EN/IEC 61800-3 4...12 kHz shielded motor cable <50 m
Conducted emissions with integrated EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 4...16 kHz shielded motor cable <5 m
Conducted emissions with integrated EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 2, 4, 8, 12 and 16 kHz shielded motor cable <10 mproduct certifications CSA
GOST
UL
NOM
C-Tickvibration resistance 1 gn (f = 13…200 Hz) conforming to EN/IEC 60068-2-6
1.5 mm peak to peak (f = 3…13 Hz) - drive unmounted on symmetrical DIN rail - conforming to EN/IEC 60068-2-6shock resistance 15 gn conforming to EN/IEC 60068-2-27 for 11 ms relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
5…95 % without dripping water conforming to IEC 60068-2-3ambient air temperature for storage -25…70 °C ambient air temperature for operation -10…50 °C protective cover from the top of the drive removed
50…60 °C with current derating 2.2 % per °Coperating altitude > 1000...2000 m with current derating 1 % per 100 m
<= 1000 m without derating
Comments