Product Filter
VitalMRO is Authorized Distributor for This Product.
range of product | Harmony XALK |
---|---|
product or component type | Complete control station |
device short name | XALK |
product destination | For XB5 Ø 22 mm control and signalling units |
control station application | Emergency switching off function Emergency stop function |
colour of base of enclosure | Light grey (RAL 7035) |
colour of cover | Yellow (RAL 1021) |
material | Polycarbonate |
operator profile | 1 mushroom head push-button |
operators description | Red unmarked 1 NC |
reset | Turn to release |
control station composition | 1 mushroom head Ø 40 mm push-button, red 1 NC unmarked marking |
contact operation | Slow-break |
cable entry 1 knock-out for cable entry 0…14 mm
2 knock-outs for Pg 13 cable gland and ISO M20 0…12 mmnet weight 0.194 kg resistance to high pressure washer 7000000 Pa at 55 °C, distance : 0.1 m positive opening With conforming to EN/IEC 60947-5-1 appendix K operating travel 1.5 mm (NC changing electrical state)
2.6 mm (NO changing electrical state)
4.3 mm (total travel)operating force 44 N NC + NO changing electrical state mechanical durability 300000 cycles connections - terminals Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN/IEC 60947-1
Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to EN/IEC 60947-1tightening torque 0.8…1.2 N.m conforming to EN/IEC 60947-1 shape of screw head Cross compatible with Philips no 1 screwdriver
Cross compatible with pozidriv No 1 screwdriver
Slotted compatible with flat Ø 4 mm screwdriver
Slotted compatible with flat Ø 5.5 mm screwdrivercontacts material Silver alloy (Ag/Ni) short-circuit protection 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1 [Ith] conventional free air thermal current 10 A conforming to EN/IEC 60947-5-1 [Ui] rated insulation voltage 600 V (pollution degree 3) conforming to EN/IEC 60947-1 [Uimp] rated impulse withstand voltage 6 kV EN/IEC 60947-1 [Ie] rated operational current 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1
6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1
0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1electrical durability 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix Celectrical reliability Λ < 10exp(-6) at 5 V, 1 mA conforming to EN/IEC 60947-5-4
Λ < 10exp(-8) at 17 V, 5 mA conforming to EN/IEC 60947-5-4
Comments