There are no items in the shopping cart.
SCHNEIDER ELECTRIC LV429004 MCCB Circuit Breaker NSX100H 100 A - 3 poles
Condition:New
Brand:SCHNEIDER ELECTRIC
Model:LV429004
Code:LV429004SCH
Weight:1.000 KG
MOQ:1.0
Number of Poles :3P
Current Rating:100A

More parameters>>

Quantity
On Hand    Group Stock    ETA Delivery   
Shipping time may vary.
VitalMRO rep will advise.


 ~ 

Product Filter

Clear All

Rated AC Voltage
Rated DC Voltage
Number Of Poles
Number of Poles
Current Rating
Current Rating
Voltage
Phase
Curve Type
Range
  • Product
  • Attribute
  • Price
  • Add To Cart

VitalMRO

Other similar brands

  • Products Detail
  • Specification parameter
  • Products Q&A
Mobile phone purchase
goods qr code
Add To Cart
Price:
Quantity:
Inventory  PcsAccount Inventory  Pcs

Products Detail

Replacement Suggest:


VitalMRO is Authorized Distributor for This Product. 


Main
range
ComPact

range of product
ComPact NSX100...250

device short name
NSX100H

product or component type
Basic frame

device application
Distribution

circuit breaker name
Compact NSX100H

Number of poles
3P

[In] rated current
100 A at 40 °C

[Ue] rated operational voltage
690 V AC 50/60 Hz

network type
AC

network frequency
50/60 Hz

suitability for isolation
Yes conforming to EN/IEC 60947-2

utilisation category
Category A

[Icu] rated ultimate short-circuit breaking capacity
10 kA at 600 V AC 50/60 Hz conforming to UL 508
85 kA at 240 V AC 50/60 Hz conforming to UL 508
65 kA at 480 V AC 50/60 Hz conforming to UL 508
10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2

Performance level
H 70 kA 415 V AC

control type
Toggle

mounting mode
Fixed

Complementary
[Ui] rated insulation voltage
800 V AC 50/60 Hz conforming to IEC 60947-2

[Uimp] rated impulse withstand voltage
8 kV conforming to IEC 60947-2

[Ics] rated service short-circuit breaking capacity
10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
70 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2

mechanical durability
50000 cycles conforming to IEC 60947-2

electrical durability
10000 cycles 690 V AC 50/60 Hz In conforming to IEC 60947-2
20000 cycles 690 V AC 50/60 Hz In/2 conforming to IEC 60947-2
30000 cycles 440 V AC 50/60 Hz In conforming to IEC 60947-2
50000 cycles 440 V AC 50/60 Hz In/2 conforming to IEC 60947-2

mounting support
Backplate

upside connection
Front

downside connection
Front

connection pitch
35 mm

protection type
Without protection

Width (W)
105 mm

Height (H)
161 mm

Depth (D)
86 mm