There are no items in the shopping cart.
Condition:[NEW - Manufacturer Packed]
Brand:SCHNEIDER ELECTRIC
Model:LUCA1XFU
Code:LUCA1XFUSCH
Weight:1.000 KG
MOQ:0
Quantity
On Hand    Group Stock    ETA Delivery   
Shipping time may vary.
VitalMRO rep will advise.


 ~ 

Product Filter

Clear All

  • Product
  • Attribute
  • Price
  • Add To Cart
  • Products Detail
  • Products Q&A
Mobile phone purchase
goods qr code
Add To Cart
Price:
Quantity:
Inventory  PcsAccount Inventory  Pcs

Products Detail

Replacement Suggest:


VitalMRO is Authorized Distributor for This Product. 


Main
rangeTeSys
range of productTeSys U
product nameTeSys U
device short nameLUCA
product or component typeStandard control unit
device applicationMotor control
Motor protection
product specific applicationBasic protection requirements for motor starters: overload and short-circuit
main function availableProtection against phase failure and phase imbalance
Protection against overload and short-circuit
Manual reset
Earth fault protection
product compatibilityPower base LUB12
Power base LUB32
Power base LUB38
Power base LUB120
Power base LUB320
Power base LUB380
Reversing contactor breaker LU2B12FU
Reversing contactor breaker LU2B32FU
Reversing contactor breaker LU2B38FU
[Ue] rated operational voltage690 V AC
network frequency40...60 Hz
load type3-phase motor - cooling: self-cooled
utilisation categoryAC-44
AC-41
AC-43
motor power kW0.25 kW at 400...440 V AC 50/60 Hz
rated motor current adjustment range0.35…1.4 A
thermal overload classClass 10 - frequency limit: 40…60 Hz - temperature compensation: -25…70 °C conforming to IEC 60947-6-2
Class 10 - frequency limit: 40…60 Hz - temperature compensation: -25…70 °C conforming to UL 508
tripping threshold14.2 x Ir +/- 20 %
phase failure sensitivityYes
[Uc] control circuit voltage110...240 V AC
110...220 V DC

Complementary
control circuit voltage limits88...264 V for AC circuit 110...240 V in operation
88...242 V for DC circuit 110...220 V in operation
55 V for AC circuit 110...240 V drop-out
55 V for DC circuit 110...220 V drop-out
typical current consumption280 mA at 110...240 V AC I maximum while closing with LUB12
280 mA at 110...240 V AC I maximum while closing with LUB32
280 mA at 110...240 V AC I maximum while closing with LUB38
280 mA at 110...220 V DC I maximum while closing with LUB12
280 mA at 110...220 V DC I maximum while closing with LUB32
280 mA at 110...220 V DC I maximum while closing with LUB38
35 mA at 110...240 V AC I rms sealed with LUB12
25 mA at 110...240 V AC I rms sealed with LUB32
25 mA at 110...240 V AC I rms sealed with LUB38
35 mA at 110...220 V DC I rms sealed with LUB12
25 mA at 110...220 V DC I rms sealed with LUB32
25 mA at 110...220 V DC I rms sealed with LUB38
heat dissipation2 W for control circuit with LUB12
3 W for control circuit with LUB32
3 W for control circuit with LUB38
operating time35 ms opening with LUB12 for control circuit
35 ms opening with LUB32 for control circuit
35 ms opening with LUB38 for control circuit
50 ms closing with LUB12 for control circuit
50 ms closing with LUB32 for control circuit
50 ms closing with LUB38 for control circuit
standardsEN 60947-6-2
IEC 60947-6-2
UL 60947-4-1, with phase barrier
CSA C22.2 No 60947-4-1, with phase barrier
product certificationsCE
UL
CSA
CCC
EAC
ASEFA
ATEX
Marine
[Ui] rated insulation voltage690 V conforming to IEC 60947-6-2
600 V conforming to UL 60947-4-1
600 V conforming to CSA C22.2 No 60947-4-1
[Uimp] rated impulse withstand voltageIEC 60947-6-2 6 kV
safe separation of circuit400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1
400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1
fixing modePlug-in (front face)
width45 mm
height66 mm
depth60 mm
net weight0.135 kg
compatibility codeLUCA


100 Rate %
I haven't set up the buyer's impression yet. Please wait with me~
No comment

User discussion circle

Subscribe to get more info
Compare

1

You can also continue adding

2

You can also continue adding

3

You can also continue adding

4

You can also continue adding