There are no items in the shopping cart.
Condition:[NEW - ORI Packed]
Brand:SCHNEIDER ELECTRIC
Model:LC1D32M7
Code:LC1D32M7SCH
Weight:0 Gram
MOQ:0
Voltage :220VAC

More parameters>>

Quantity
On Hand    Group Stock    ETA Delivery    Ex-Stocks
Shipping time may vary.
VitalMRO rep will advise.


 ~ 

Product Filter

Clear All

Coil Voltage (DC)
Current Rating
Coil Voltage (AC)
Number of Poles
Number of NO Aux.Contacts
Voltage
  • Product
  • Attribute
  • Price
  • Add To Cart
  • Products Detail
  • Specification parameter
  • Products Q&A
Mobile phone purchase
goods qr code
Add To Cart
Price:
Quantity:
Inventory  PcsAccount Inventory  Pcs

Products Detail

Replacement Suggest:


VitalMRO is Authorized Distributor for This Product. 


Main
range
TeSys

product name
TeSys D

product or component type
Contactor

device short name
LC1D

contactor application
Resistive load
Motor control

utilisation category
AC-4
AC-1
AC-3

poles description
3P

power pole contact composition
3 NO

[Ue] rated operational voltage
Power circuit: <= 690 V AC 25...400 Hz
Power circuit: <= 300 V DC

[Ie] rated operational current
32 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit

motor power kW
7.5 kW at 220...230 V AC 50/60 Hz (AC-3)
15 kW at 380...400 V AC 50/60 Hz (AC-3)
15 kW at 415...440 V AC 50/60 Hz (AC-3)
18.5 kW at 500 V AC 50/60 Hz (AC-3)
18.5 kW at 660...690 V AC 50/60 Hz (AC-3)
7.5 kW at 400 V AC 50/60 Hz (AC-4)

motor power HP (UL / CSA)
2 hp at 115 V AC 50/60 Hz for 1 phase motors
5 hp at 230/240 V AC 50/60 Hz for 1 phase motors
7.5 hp at 200/208 V AC 50/60 Hz for 3 phases motors
10 hp at 230/240 V AC 50/60 Hz for 3 phases motors
20 hp at 460/480 V AC 50/60 Hz for 3 phases motors
30 hp at 575/600 V AC 50/60 Hz for 3 phases motors

control circuit type
AC at 50/60 Hz

[Uc] control circuit voltage
220 V AC 50/60 Hz

auxiliary contact composition
1 NO + 1 NC

[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947

overvoltage category
III

[Ith] conventional free air thermal current
10 A (at 60 °C) for signalling circuit
50 A (at 60 °C) for power circuit

Irms rated making capacity
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
550 A at 440 V for power circuit conforming to IEC 60947

rated breaking capacity
550 A at 440 V for power circuit conforming to IEC 60947

[Icw] rated short-time withstand current
260 A 40 °C - 10 s for power circuit
430 A 40 °C - 1 s for power circuit
60 A 40 °C - 10 min for power circuit
138 A 40 °C - 1 min for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit

associated fuse rating
10 A gG for signalling circuit conforming to IEC 60947-5-1
63 A gG at <= 690 V coordination type 1 for power circuit
63 A gG at <= 690 V coordination type 2 for power circuit

average impedance
2 mOhm - Ith 50 A 50 Hz for power circuit

[Ui] rated insulation voltage
Power circuit: 690 V conforming to IEC 60947-4-1
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified

electrical durability
1.65 Mcycles 32 A AC-3 at Ue <= 440 V
1.4 Mcycles 50 A AC-1 at Ue <= 440 V

power dissipation per pole
2 W AC-3
5 W AC-1

Front cover
With

mounting support
Plate
Rail

standards
CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508

product certifications
DNV
RINA
LROS (Lloyds register of shipping)
CCC
CSA
GL
GOST
BV
UL

connections - terminals
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Power circuit: screw clamp terminals 1 cable(s) 2.5…10 mm²flexible without cable end
Power circuit: screw clamp terminals 2 cable(s) 2.5…10 mm²flexible without cable end
Power circuit: screw clamp terminals 1 cable(s) 1…10 mm²flexible with cable end
Power circuit: screw clamp terminals 2 cable(s) 1.5…6 mm²flexible with cable end
Power circuit: screw clamp terminals 1 cable(s) 1.5…10 mm²solid without cable end
Power circuit: screw clamp terminals 2 cable(s) 2.5…10 mm²solid without cable end

tightening torque
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2

operating time
12...22 ms closing
4...19 ms opening

safety reliability level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1

mechanical durability
15 Mcycles

maximum operating rate
3600 cyc/h 60 °C

Complementary
coil technology
Without built-in suppressor module

control circuit voltage limits
0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz
1...1.1 Uc (60…70 °C):operational AC 50/60 Hz

inrush power in VA
70 VA 60 Hz cos phi 0.75 (at 20 °C)
70 VA 50 Hz cos phi 0.75 (at 20 °C)

hold-in power consumption in VA
7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
7 VA 50 Hz cos phi 0.3 (at 20 °C)

heat dissipation
2…3 W at 50/60 Hz

auxiliary contacts type

Specification parameter

Attribute

Voltage
220VAC
100 Rate %
I haven't set up the buyer's impression yet. Please wait with me~
No comment

User discussion circle

Subscribe to get more info
Compare

1

You can also continue adding

2

You can also continue adding

3

You can also continue adding

4

You can also continue adding